fda standard normal tissues Search Results


94
KCAS Bioanalytical and Biomarker Services biomarkers limonene
Biomarkers Limonene, supplied by KCAS Bioanalytical and Biomarker Services, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/biomarkers limonene/product/KCAS Bioanalytical and Biomarker Services
Average 94 stars, based on 1 article reviews
biomarkers limonene - by Bioz Stars, 2026-05
94/100 stars
  Buy from Supplier

93
Novus Biologicals mesothelioma
Representative immunofluorescent staining of cultured <t>mesothelioma</t> cells using AX10 antibody (a), immunohistochemical staining (b), and secondary antibody‐drug conjugate assay in vitro (c). (a) AX10 immunoreactivity in MPM‐1, −2, and −3 cells, representing sarcomatoid, epithelioid, and biphasic type mesothelioma, respectively. All MPM‐1, −2, and −3 cells exhibited AX10 antibody immunoreactivity at the cell surface. The staining was analyzed using a Guava easyCyte cell analyzer and accompanying software to obtain a one‐parameter log histogram. (b) AX10 immunoreactivity in various mesothelioma tissue specimens. Weak or no AX10 immunoreactivity was detected in five out of 10 epithelioid mesothelioma tissues (a). One out of five biphasic mesotheliomas exhibited AX10 immunoreactivity in spindle sarcomatoid components (arrow) but weak immunoreactivity in epithelioid components (arrowhead) (b). Five out of six sarcomatoid mesothelioma tissues exhibited strong AX10 immunoreactivity (c). Little AX10 immunoreactivity was detected in normal human tissues. No significant AX10 immunoreactivity was detected in the lung (d) (pleural mesothelial cells; insert) tissue specimens. Weak AX10 immunoreactivity was detected in myofibrous cells in the uterus (e). We did not detect any significant AX10 immunoreactivity in the brain, liver, or kidney, whereas strong AX10 immunoreactivity was observed in a nonmelanocytic (hypomelanocytic) melanoma tissue sample that was supplementally included in the microarray (f) (staining without AX10 antibody; insert). (c) MPM‐1 sarcomatoid mesothelioma cells were incubated with AX10 at 10, 100, and 1000 ng/mL followed by incubation with anti‐murine IgG (Fc) antibody conjugated to duocarmycin. Representative staining with Annexin V‐PI is presented. Note the dose‐dependent Annexin V‐positive and PI‐negative apoptotic MPM‐1 cells in the presence of AX10 antibody
Mesothelioma, supplied by Novus Biologicals, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/mesothelioma/product/Novus Biologicals
Average 93 stars, based on 1 article reviews
mesothelioma - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

93
Novus Biologicals tissue microarrays
Representative immunofluorescent staining of cultured <t>mesothelioma</t> cells using AX10 antibody (a), immunohistochemical staining (b), and secondary antibody‐drug conjugate assay in vitro (c). (a) AX10 immunoreactivity in MPM‐1, −2, and −3 cells, representing sarcomatoid, epithelioid, and biphasic type mesothelioma, respectively. All MPM‐1, −2, and −3 cells exhibited AX10 antibody immunoreactivity at the cell surface. The staining was analyzed using a Guava easyCyte cell analyzer and accompanying software to obtain a one‐parameter log histogram. (b) AX10 immunoreactivity in various mesothelioma tissue specimens. Weak or no AX10 immunoreactivity was detected in five out of 10 epithelioid mesothelioma tissues (a). One out of five biphasic mesotheliomas exhibited AX10 immunoreactivity in spindle sarcomatoid components (arrow) but weak immunoreactivity in epithelioid components (arrowhead) (b). Five out of six sarcomatoid mesothelioma tissues exhibited strong AX10 immunoreactivity (c). Little AX10 immunoreactivity was detected in normal human tissues. No significant AX10 immunoreactivity was detected in the lung (d) (pleural mesothelial cells; insert) tissue specimens. Weak AX10 immunoreactivity was detected in myofibrous cells in the uterus (e). We did not detect any significant AX10 immunoreactivity in the brain, liver, or kidney, whereas strong AX10 immunoreactivity was observed in a nonmelanocytic (hypomelanocytic) melanoma tissue sample that was supplementally included in the microarray (f) (staining without AX10 antibody; insert). (c) MPM‐1 sarcomatoid mesothelioma cells were incubated with AX10 at 10, 100, and 1000 ng/mL followed by incubation with anti‐murine IgG (Fc) antibody conjugated to duocarmycin. Representative staining with Annexin V‐PI is presented. Note the dose‐dependent Annexin V‐positive and PI‐negative apoptotic MPM‐1 cells in the presence of AX10 antibody
Tissue Microarrays, supplied by Novus Biologicals, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/tissue microarrays/product/Novus Biologicals
Average 93 stars, based on 1 article reviews
tissue microarrays - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

93
Novus Biologicals fda standard tissue array
Representative immunofluorescent staining of cultured <t>mesothelioma</t> cells using AX10 antibody (a), immunohistochemical staining (b), and secondary antibody‐drug conjugate assay in vitro (c). (a) AX10 immunoreactivity in MPM‐1, −2, and −3 cells, representing sarcomatoid, epithelioid, and biphasic type mesothelioma, respectively. All MPM‐1, −2, and −3 cells exhibited AX10 antibody immunoreactivity at the cell surface. The staining was analyzed using a Guava easyCyte cell analyzer and accompanying software to obtain a one‐parameter log histogram. (b) AX10 immunoreactivity in various mesothelioma tissue specimens. Weak or no AX10 immunoreactivity was detected in five out of 10 epithelioid mesothelioma tissues (a). One out of five biphasic mesotheliomas exhibited AX10 immunoreactivity in spindle sarcomatoid components (arrow) but weak immunoreactivity in epithelioid components (arrowhead) (b). Five out of six sarcomatoid mesothelioma tissues exhibited strong AX10 immunoreactivity (c). Little AX10 immunoreactivity was detected in normal human tissues. No significant AX10 immunoreactivity was detected in the lung (d) (pleural mesothelial cells; insert) tissue specimens. Weak AX10 immunoreactivity was detected in myofibrous cells in the uterus (e). We did not detect any significant AX10 immunoreactivity in the brain, liver, or kidney, whereas strong AX10 immunoreactivity was observed in a nonmelanocytic (hypomelanocytic) melanoma tissue sample that was supplementally included in the microarray (f) (staining without AX10 antibody; insert). (c) MPM‐1 sarcomatoid mesothelioma cells were incubated with AX10 at 10, 100, and 1000 ng/mL followed by incubation with anti‐murine IgG (Fc) antibody conjugated to duocarmycin. Representative staining with Annexin V‐PI is presented. Note the dose‐dependent Annexin V‐positive and PI‐negative apoptotic MPM‐1 cells in the presence of AX10 antibody
Fda Standard Tissue Array, supplied by Novus Biologicals, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fda standard tissue array/product/Novus Biologicals
Average 93 stars, based on 1 article reviews
fda standard tissue array - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

91
Novus Biologicals human fda standard tissue microarray
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
Human Fda Standard Tissue Microarray, supplied by Novus Biologicals, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/human fda standard tissue microarray/product/Novus Biologicals
Average 91 stars, based on 1 article reviews
human fda standard tissue microarray - by Bioz Stars, 2026-05
91/100 stars
  Buy from Supplier

93
KCAS Bioanalytical and Biomarker Services hybrid immunocapture lc ms ms
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
Hybrid Immunocapture Lc Ms Ms, supplied by KCAS Bioanalytical and Biomarker Services, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hybrid immunocapture lc ms ms/product/KCAS Bioanalytical and Biomarker Services
Average 93 stars, based on 1 article reviews
hybrid immunocapture lc ms ms - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

99
KCAS Bioanalytical and Biomarker Services kcas bio analytical
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
Kcas Bio Analytical, supplied by KCAS Bioanalytical and Biomarker Services, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/kcas bio analytical/product/KCAS Bioanalytical and Biomarker Services
Average 99 stars, based on 1 article reviews
kcas bio analytical - by Bioz Stars, 2026-05
99/100 stars
  Buy from Supplier

90
BioChain Institute fda standard panel of healthy tissue
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
Fda Standard Panel Of Healthy Tissue, supplied by BioChain Institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fda standard panel of healthy tissue/product/BioChain Institute
Average 90 stars, based on 1 article reviews
fda standard panel of healthy tissue - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Pantomics Inc 33 types of normal tissues based on the fda recommendation for antibody cross-reactivity testing
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
33 Types Of Normal Tissues Based On The Fda Recommendation For Antibody Cross Reactivity Testing, supplied by Pantomics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/33 types of normal tissues based on the fda recommendation for antibody cross-reactivity testing/product/Pantomics Inc
Average 90 stars, based on 1 article reviews
33 types of normal tissues based on the fda recommendation for antibody cross-reactivity testing - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ProteoGenex Inc full fda panel of normal human tissues on tissue microarray (tma)
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
Full Fda Panel Of Normal Human Tissues On Tissue Microarray (Tma), supplied by ProteoGenex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/full fda panel of normal human tissues on tissue microarray (tma)/product/ProteoGenex Inc
Average 90 stars, based on 1 article reviews
full fda panel of normal human tissues on tissue microarray (tma) - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
BioChain Institute fda standard frozen tissue rat or human arrays
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
Fda Standard Frozen Tissue Rat Or Human Arrays, supplied by BioChain Institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fda standard frozen tissue rat or human arrays/product/BioChain Institute
Average 90 stars, based on 1 article reviews
fda standard frozen tissue rat or human arrays - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
BioChain Institute frozen normal mouse tissue panel fda standard
Tissue <t>microarray</t> stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.
Frozen Normal Mouse Tissue Panel Fda Standard, supplied by BioChain Institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/frozen normal mouse tissue panel fda standard/product/BioChain Institute
Average 90 stars, based on 1 article reviews
frozen normal mouse tissue panel fda standard - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Representative immunofluorescent staining of cultured mesothelioma cells using AX10 antibody (a), immunohistochemical staining (b), and secondary antibody‐drug conjugate assay in vitro (c). (a) AX10 immunoreactivity in MPM‐1, −2, and −3 cells, representing sarcomatoid, epithelioid, and biphasic type mesothelioma, respectively. All MPM‐1, −2, and −3 cells exhibited AX10 antibody immunoreactivity at the cell surface. The staining was analyzed using a Guava easyCyte cell analyzer and accompanying software to obtain a one‐parameter log histogram. (b) AX10 immunoreactivity in various mesothelioma tissue specimens. Weak or no AX10 immunoreactivity was detected in five out of 10 epithelioid mesothelioma tissues (a). One out of five biphasic mesotheliomas exhibited AX10 immunoreactivity in spindle sarcomatoid components (arrow) but weak immunoreactivity in epithelioid components (arrowhead) (b). Five out of six sarcomatoid mesothelioma tissues exhibited strong AX10 immunoreactivity (c). Little AX10 immunoreactivity was detected in normal human tissues. No significant AX10 immunoreactivity was detected in the lung (d) (pleural mesothelial cells; insert) tissue specimens. Weak AX10 immunoreactivity was detected in myofibrous cells in the uterus (e). We did not detect any significant AX10 immunoreactivity in the brain, liver, or kidney, whereas strong AX10 immunoreactivity was observed in a nonmelanocytic (hypomelanocytic) melanoma tissue sample that was supplementally included in the microarray (f) (staining without AX10 antibody; insert). (c) MPM‐1 sarcomatoid mesothelioma cells were incubated with AX10 at 10, 100, and 1000 ng/mL followed by incubation with anti‐murine IgG (Fc) antibody conjugated to duocarmycin. Representative staining with Annexin V‐PI is presented. Note the dose‐dependent Annexin V‐positive and PI‐negative apoptotic MPM‐1 cells in the presence of AX10 antibody

Journal: Thoracic Cancer

Article Title: Tumor suppressor effect of an antibody on xenotransplanted sarcomatoid mesothelioma cells

doi: 10.1111/1759-7714.14591

Figure Lengend Snippet: Representative immunofluorescent staining of cultured mesothelioma cells using AX10 antibody (a), immunohistochemical staining (b), and secondary antibody‐drug conjugate assay in vitro (c). (a) AX10 immunoreactivity in MPM‐1, −2, and −3 cells, representing sarcomatoid, epithelioid, and biphasic type mesothelioma, respectively. All MPM‐1, −2, and −3 cells exhibited AX10 antibody immunoreactivity at the cell surface. The staining was analyzed using a Guava easyCyte cell analyzer and accompanying software to obtain a one‐parameter log histogram. (b) AX10 immunoreactivity in various mesothelioma tissue specimens. Weak or no AX10 immunoreactivity was detected in five out of 10 epithelioid mesothelioma tissues (a). One out of five biphasic mesotheliomas exhibited AX10 immunoreactivity in spindle sarcomatoid components (arrow) but weak immunoreactivity in epithelioid components (arrowhead) (b). Five out of six sarcomatoid mesothelioma tissues exhibited strong AX10 immunoreactivity (c). Little AX10 immunoreactivity was detected in normal human tissues. No significant AX10 immunoreactivity was detected in the lung (d) (pleural mesothelial cells; insert) tissue specimens. Weak AX10 immunoreactivity was detected in myofibrous cells in the uterus (e). We did not detect any significant AX10 immunoreactivity in the brain, liver, or kidney, whereas strong AX10 immunoreactivity was observed in a nonmelanocytic (hypomelanocytic) melanoma tissue sample that was supplementally included in the microarray (f) (staining without AX10 antibody; insert). (c) MPM‐1 sarcomatoid mesothelioma cells were incubated with AX10 at 10, 100, and 1000 ng/mL followed by incubation with anti‐murine IgG (Fc) antibody conjugated to duocarmycin. Representative staining with Annexin V‐PI is presented. Note the dose‐dependent Annexin V‐positive and PI‐negative apoptotic MPM‐1 cells in the presence of AX10 antibody

Article Snippet: Tissue microarrays composed of mesothelioma (Cat. No. MS801b) and Food and Drug Administration (FDA) normal organ tissue arrays (Cat. No. NBP2‐78057) were purchased from US Biomax and Novus Biologicals, respectively.

Techniques: Staining, Cell Culture, Immunohistochemical staining, In Vitro, Software, Microarray, Incubation

AX10 does not affect cell proliferation, but significantly decreases Matrigel invasion activity of MPM‐1 sarcomatoid mesothelioma cells in vitro. (a) Representative cell proliferation assay. At 24 h, the cell number was 1.80 ± 0.10 (mock) and 1.77 ± 0.06 (AX10). Respective numbers at 48 h were 2.40 ± 0.10 (mock) and 2.37 ± 0.12 (AX10), while at 72 h they were 3.90 ± 0.20 (mock) and 4.20 ± 0.61 (AX10). The data represent means ± SD from triplicate assays (Student's t ‐test, p > 0.5). (b) AX10 significantly reduced Matrigel invasion activity of MPM‐1 cells (Student's t ‐test, p < 0.01). The number of invading cells was 59.7 ± 7.02 (mock) and 10.3 ± 1.52 (AX10) at 24 h, and 210.7 ± 11.4 (mock) and 15.0 ± 3.00 (AX10) at 48 h. Data from triplicate assays are expressed as means ± SD ( n = 3). (c) Cells that migrated to the lower surface of the membrane are shown (48 h). Original magnification, ×100

Journal: Thoracic Cancer

Article Title: Tumor suppressor effect of an antibody on xenotransplanted sarcomatoid mesothelioma cells

doi: 10.1111/1759-7714.14591

Figure Lengend Snippet: AX10 does not affect cell proliferation, but significantly decreases Matrigel invasion activity of MPM‐1 sarcomatoid mesothelioma cells in vitro. (a) Representative cell proliferation assay. At 24 h, the cell number was 1.80 ± 0.10 (mock) and 1.77 ± 0.06 (AX10). Respective numbers at 48 h were 2.40 ± 0.10 (mock) and 2.37 ± 0.12 (AX10), while at 72 h they were 3.90 ± 0.20 (mock) and 4.20 ± 0.61 (AX10). The data represent means ± SD from triplicate assays (Student's t ‐test, p > 0.5). (b) AX10 significantly reduced Matrigel invasion activity of MPM‐1 cells (Student's t ‐test, p < 0.01). The number of invading cells was 59.7 ± 7.02 (mock) and 10.3 ± 1.52 (AX10) at 24 h, and 210.7 ± 11.4 (mock) and 15.0 ± 3.00 (AX10) at 48 h. Data from triplicate assays are expressed as means ± SD ( n = 3). (c) Cells that migrated to the lower surface of the membrane are shown (48 h). Original magnification, ×100

Article Snippet: Tissue microarrays composed of mesothelioma (Cat. No. MS801b) and Food and Drug Administration (FDA) normal organ tissue arrays (Cat. No. NBP2‐78057) were purchased from US Biomax and Novus Biologicals, respectively.

Techniques: Activity Assay, In Vitro, Proliferation Assay, Membrane

Inhibitory effect of AX10 on MPM‐1 xenotransplanted sarcomatoid mesothelioma cell proliferation. (a) Inoculation of AX10 antibody delayed the growth of xenotransplanted MPM‐1 sarcomatoid mesothelioma tumors. On day 0, SCID‐NOD mice were subcutaneously implanted with MPM‐1 cells. The following day, day 3, the mice were administered AX10 antibody or vehicle only by intraperitoneal injection and weekly thereafter as indicated by arrows. Values are represented as means ± standard error for n = 5 mice. Statistical significance was measured by a two‐sided unpaired Student's t ‐test (* p < 0.01). (b) On day 42, the xenotransplanted tumors were excised to determine their weight. Total tumor weights are represented as means ± standard error for n = 5 mice. Statistical significance was measured by a two‐sided unpaired Student's t ‐test ( p < 0.01). (c) Gross and histological appearance of a representative xenotransplanted tumor. Arrowhead indicates the tumor without AX10 antibody, while the arrow indicates the small tumor remaining following weekly AX10 injection. Note the elimination of tumor cells, which were histologically replaced by regenerative muscle in mice inoculated with AX10 antibody. Scale bar indicates 100 μm

Journal: Thoracic Cancer

Article Title: Tumor suppressor effect of an antibody on xenotransplanted sarcomatoid mesothelioma cells

doi: 10.1111/1759-7714.14591

Figure Lengend Snippet: Inhibitory effect of AX10 on MPM‐1 xenotransplanted sarcomatoid mesothelioma cell proliferation. (a) Inoculation of AX10 antibody delayed the growth of xenotransplanted MPM‐1 sarcomatoid mesothelioma tumors. On day 0, SCID‐NOD mice were subcutaneously implanted with MPM‐1 cells. The following day, day 3, the mice were administered AX10 antibody or vehicle only by intraperitoneal injection and weekly thereafter as indicated by arrows. Values are represented as means ± standard error for n = 5 mice. Statistical significance was measured by a two‐sided unpaired Student's t ‐test (* p < 0.01). (b) On day 42, the xenotransplanted tumors were excised to determine their weight. Total tumor weights are represented as means ± standard error for n = 5 mice. Statistical significance was measured by a two‐sided unpaired Student's t ‐test ( p < 0.01). (c) Gross and histological appearance of a representative xenotransplanted tumor. Arrowhead indicates the tumor without AX10 antibody, while the arrow indicates the small tumor remaining following weekly AX10 injection. Note the elimination of tumor cells, which were histologically replaced by regenerative muscle in mice inoculated with AX10 antibody. Scale bar indicates 100 μm

Article Snippet: Tissue microarrays composed of mesothelioma (Cat. No. MS801b) and Food and Drug Administration (FDA) normal organ tissue arrays (Cat. No. NBP2‐78057) were purchased from US Biomax and Novus Biologicals, respectively.

Techniques: Injection

Tissue microarray stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.

Journal: EMBO Molecular Medicine

Article Title: A human monoclonal antibody bivalently binding two different epitopes in streptococcal M protein mediates immune function

doi: 10.15252/emmm.202216208

Figure Lengend Snippet: Tissue microarray stained with 10 μg/ml of Xolair, Ab25, 32, and 49, or 2.5% plasma, 500 μg/ml IVIG or 1:100 anti‐Troponin antibody. Each spot is a sampling from different tissue. Tissue sections are 6 μm thick, 1.5 mm wide, and were mounted on positively charged glass slides. None of the tissues showed reactivity with the monoclonal samples, except the positive control anti‐Troponin, which was reactive with cardiac tissue, as shown. Out of the 30 tissue types present on the slides, the cardiac samples would otherwise be the tissue type that had the largest risk of reactivity due to the M‐protein mimicry with heart tissue. Zoomed in images of tissue spots representing cardiac tissue. Sequence alignment between M1 protein and tropomyosin. The highlighted area indicates identified the cross‐linked peptide (closest to the interaction site) between Ab25 and Ab49.

Article Snippet: Human FDA Standard Tissue MicroArray (Normal) , Novus Biologicals , NBP2‐78123.

Techniques: Microarray, Staining, Clinical Proteomics, Sampling, Positive Control, Sequencing

Journal: EMBO Molecular Medicine

Article Title: A human monoclonal antibody bivalently binding two different epitopes in streptococcal M protein mediates immune function

doi: 10.15252/emmm.202216208

Figure Lengend Snippet:

Article Snippet: Human FDA Standard Tissue MicroArray (Normal) , Novus Biologicals , NBP2‐78123.

Techniques: Virus, Clinical Proteomics, Recombinant, Saline, Staining, Labeling, Plasmid Preparation, Microarray